Medtronic ClosureFast™ Endovenous Radiofrequency Ablation Catheter, 7 Fr × 100 cm, 7 cm Heating Element
Tags:
$649.00
Customize
Device Identifier (DI)
00763000702274 Device Identifier (DI) Information
AccessGUDID Identifiers (Synced)
[Package DI] Not reported [Secondary DI] Not reported [Unit of Use DI] Not reported All Package, Secondary, and Unit of Use DIs from the record matched by the manually entered Device Identifier.
AccessGUDID
AccessGUDID RecordLink to Medical Device Record on AccessGUDID
GMDN Term Code & Name (Synced)
62233 | Peripheral vascular electrocautery catheter, single-use All GMDN codes and term names returned by the exact manually entered DI. Full definitions are stored separately.
GMDN Term Definition (Synced)
A flexible catheter with a distal heating element/electrode intended to be connected to an electrical generator and introduced into the peripheral vasculature to ablate venous tissues, through direct application of heat, as a treatment for venous reflux disease (varicose veins); it is not intended to introduce electrical current into the body. It is a luminal device with a proximal handle with controls (e.g., on/off switch) that is introduced via an introducer assembly (which may be included), and is typically maneuvered under external image guidance [e.g., ultrasound (US)]. This is a single-use device. Full AccessGUDID GMDN definitions, one entry per term with its code. Kept separate from GMDN Term Code and Term Name.
AccessGUDID Device Details (Synced)
[Company Name] MEDTRONIC, INC. [Device Description] CATHETER CF7-7-100 CLOSURE FAST V05 [FDA Product Code] GEI | Electrosurgical, cutting & coagulation & accessories [Sterilization Method] Not reported [Storage and Handling] Special Storage Condition, Specify Store the device in a dry area away from sunlight. [Size Type Text] Length: 7.0 Centimeter Device Size Text, specify: Introducer sheath: 7 Fr Length: 100.0 Centimeter Company name, device description, FDA codes, sterilization method, storage and handling, and size. Each labeled section preserves every API value.
For Single-Use (Synced)
Yes Synced from the exact entered DI in AccessGUDID. Values are Yes, No, or Not reported; missing data is never treated as No.
Prescription Use (Rx) (Synced)
Yes Synced from the exact entered DI in AccessGUDID. Values are Yes, No, or Not reported; missing data is never treated as No.
Over the Counter (OTC) (Synced)
No Synced from the exact entered DI in AccessGUDID. Values are Yes, No, or Not reported; missing data is never treated as No.
Kit (Synced)
No Synced from the exact entered DI in AccessGUDID. Values are Yes, No, or Not reported; missing data is never treated as No.
Combination Product (Synced)
No Synced from the exact entered DI in AccessGUDID. Values are Yes, No, or Not reported; missing data is never treated as No.
Product Details
Ratings & Reviews
Product Details
Product Details
The Medtronic ClosureFast™ CF7-7-100 is a sterile, single-use endovenous radiofrequency ablation catheter with a 100 cm insertable length and a 7 cm heating element. It uses radiofrequency-generated heat to coagulate and close targeted blood vessels in patients with superficial vein reflux. Designed for use with a compatible ClosureRFG™ generator, the catheter requires a minimum 7 Fr introducer sheath and accommodates a 0.025-inch guidewire. Use in accordance with the manufacturer’s instructions.
Ratings & Reviews